• Bently Nevada 9200-03-05-10-00 Two-wire Transducer
  • Bently Nevada 9200-03-05-10-00 Two-wire Transducer
  • Bently Nevada 9200-03-05-10-00 Two-wire Transducer
  • Bently Nevada 9200-03-05-10-00 Two-wire Transducer

Bently Nevada 9200-03-05-10-00 Two-wire Transducer

Item no: 9200-03-05-10-00

Brand: Bently Nevada

Price:$ 1300

Delivery time: In Stock

$1300.00
  • Bently Nevada 9200-03-05-10-00 Two-wire Transducer
  • Bently Nevada 9200-03-05-10-00 Two-wire Transducer
Description

Description

Bently Nevada Seismoprobe Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The two-wire systems consist of a transducer and appropriate cable.

The Seismoprobe family of velocity transducers is a two-wire design that uses moving-coil technology. It provides a voltage output directly proportional to the transducer's vibration velocity.

Moving-coil transducers are less sensitive to impact or impulsive excitation than solid-state velocity transducers, which are inherently accelerometers with embedded integration electronics.

Moving-coil transducers are less sensitive to impact or impulsive excitation and can represent a good choice for certain applications. Because they don’t require external power, they are convenient for portable measurement applications.

For most installations, Bently Nevada's Velomitor family of velocity transducers, which incorporate solid-state technology, provide improved performance and ruggedness for casing velocity measurement applications.

Ordering Information

For the detailed listing of country and product specific approvals, refer to the Approvals Quick Reference Guide (document 108M1756) at Bently.com.

An isolated base (‘06’ thru ‘09’, or ‘11’, ‘12’ in Mounting Base Option) is required when ‘04’ Agency Approval Option is selected.

Two-wire Transducer

9200 - AA-BB-CC-DD

A:

Transducer Mounting Angle/Minimum  Operating Frequency Option

01      0 ±2.5, 4.5 Hz (270 cpm)

02      45 ±2.5, 4.5 Hz (270 cpm)

03      90 ±2.5, 4.5 Hz (270 cpm)

06      0 ±100, 10 Hz (600 cpm)

09      0 ±180, 15 Hz (900 cpm

B: Connector/Cable Option

01      Top Mount (no cable)

02      Side Mount (no cable)

05      Terminal block top mount (no cable)

10 through 50

Integral hardline cable (see Figure 7 for example). Option number corresponds to cable length in feet. Standard cable lengths are shown below. Other cable lengths between 7 feet and 50 feet may be available through custom products. When ordering for hazardous area

10      10 feet (3.0 metres)

15      15 feet (4.6 metres)

22      22 feet (6.7 metres)

32      32 feet (9.8 metres)

50      50 feet (15.2 metres)

C: Mounting Base Option

01      Circular; 1/4-in 20 UNC stud

02      Circular; 1/4-in 28 UNF stud

03      Rectangular flange

04      Circular; with three 8-32 threaded studs on a 44 mm (1.75 in) diameter bolt circle

05      No base; 1/2-in 20 UNF-3A stud

06      Isolated circular 1/4-in 20 UNC stud

07      Isolated circular 1/4-in 28 UNF stud

08      Isolated rectangular flange

09      Isolated circular 5/8-in 18 UNF stud

10      Circular; M10X1 stud

11      Isolated circular M10X1

12      Isolated circular ½-in 20 UNF-2A

D: Agency Approval Option

00      No Approvals

01      CSA

04       ATEX/IECEx